图书简介
Data centers consume roughly 1% of the total electricity demand, while ICT as a whole consumes around 10%. Demand is growing exponentially and, left unchecked, will grow to an estimated increase of 20% or more by 2030. This book covers the energy consumption and minimization of the different data center components when running real workloads, taking into account the types of instructions executed by the servers. It presents the different air- and liquid-cooled technologies for servers and data centers with some real examples, including waste heat reuse through adsorption chillers, as well as the hardware and software used to measure, model and control energy. It computes and compares the Power Usage Effectiveness and the Total Cost of Ownership of new and existing data centers with different cooling designs, including free cooling and waste heat reuse leading to the Energy Reuse Effectiveness. The book concludes by demonstrating how a well-designed data center reusing waste heat to produce chilled water can reduce energy consumption by roughly 50%, and how renewable energy can be used to create net-zero energy data centers.
Introduction ix Chapter 1. Systems in Data Centers 1 1.1. Servers 1 1.2. Storage arrays 3 1.3. Data center networking 4 1.4. Components 5 1.4.1. Central processing unit 5 1.4.2. Graphics processing unit 7 1.4.3. Volatile memory 8 1.4.4. Non-volatile memory 10 1.4.5. Non-volatile storage 10 1.4.6. Spinning disks and tape storage 13 1.4.7. Motherboard 15 1.4.8. PCIe I/O cards 16 1.4.9. Power supplies 17 1.4.10. Fans 18 Chapter 2. Cooling Servers 19 2.1. Evolution of cooling for mainframe, midrange and distributed computers from the 1960s to 1990s 19 2.2. Emergence of cooling for scale out computers from 1990s to 2010s 20 2.3. Chassis and rack cooling methods 23 2.4. Metrics considered for cooling 27 2.4.1. Efficiency 27 2.4.2. Reliability cost 28 2.4.3. Thermal performance 29 2.5. Material used for cooling 31 2.6. System layout and cooling air flow optimization 32 Chapter 3. Cooling the Data Center 37 3.1. System cooling technologies used 37 3.2. Air-cooled data center 38 3.2.1. Conventional air-cooled data center 38 3.3. ASHRAE data center cooling standards 40 3.3.1. Operation and temperature classes 40 3.3.2. Liquid cooling classes 41 3.3.3. Server and rack power trend 42 3.4. Liquid-cooled racks 43 3.5. Liquid-cooled servers 46 3.5.1. Water heat capacity 46 3.5.2. Thermal conduction module 47 3.5.3. Full node heat removal with cold plates 48 3.5.4. Modular heat removal with cold plates 50 3.5.5. Immersion cooling 50 3.5.6. Recent DWC servers 51 3.6. Free cooling 54 3.7. Waste heat reuse 54 3.7.1. Reusing heat as heat 54 3.7.2. Transforming heat with adsorption chillers 55 Chapter 4. Power Consumption of Servers and Workloads 65 4.1. Trends in power consumption for processors 65 4.1.1. Moore’s and Dennard’s laws 68 4.1.2. Floating point instructions on Xeon processors 72 4.1.3. CPU frequency of instructions on Intel Xeon processors 73 4.2. Trends in power consumption for GPUs 74 4.2.1. Moore’s and Dennard’s laws 77 4.3. ACPI states 78 4.4. The power equation 83 Chapter 5. Power and Performance of Workloads 87 5.1. Power and performance of workloads 87 5.1.1. SKU power and performance variations 87 5.1.2. System parameters 89 5.1.3. Workloads used 92 5.1.4. CPU-bound and memory-bound workloads 92 5.1.5. DC node power versus components power 93 5.2. Power, thermal and performance on air-cooled servers with Intel Xeon 94 5.2.1. Frequency, power and performance of simple SIMD instructions 95 5.2.2. Power, thermal and performance behavior of HPL 98 5.2.3. Power, thermal and performance behavior of STREAM 103 5.2.4. Power, thermal and performance behavior of real workloads 107 5.2.5. Power, thermal and frequency differences between CPUs 115 5.3. Power, thermal and performance on water-cooled servers with Intel Xeon 124 5.3.1. Impact on CPU temperature 124 5.3.2. Impact on voltage and frequency 125 5.3.3. Impact on power consumption and performance 127 5.4. Conclusions on the impact of cooling on power and performance 131 Chapter 6. Monitoring and Controlling Power and Performance of Servers and Data Centers 133 6.1. Monitoring power and performance of servers 133 6.1.1. Sensors and APIs for power and thermal monitoring on servers 134 6.1.2. Monitoring performance on servers 140 6.2. Modeling power and performance of servers 142 6.2.1. Cycle-accurate performance models 142 6.2.2. Descriptive models 142 6.2.3. Predictive models 144 6.3. Software to optimize power and energy of servers 149 6.3.1. LoadLeveler job scheduler with energy aware feature 150 6.3.2. Energy Aware Runtime (EAR) 151 6.3.3. Other run time systems to manage power 153 6.4. Monitoring, controlling and optimizing the data center 154 6.4.1. Monitoring the data center 154 6.4.2. Integration of the data center infrastructure with the IT devices 156 Chapter 7. PUE, ERE and TCO of Various Cooling Solutions 159 7.1. Power usage effectiveness, energy reuse effectiveness and total cost of ownership 159 7.1.1. Power usage effectiveness and energy reuse effectiveness 159 7.1.2. PUE and free cooling 162 7.1.3. ERE and waste heat reuse 163 7.2. Examples of data centers PUE and EREs 164 7.2.1. NREL Research Support Facility, CO 164 7.2.2. Leibnitz Supercomputing data center in Germany 166 7.3. Impact of cooling on TCO with no waste heat reuse 173 7.3.1. Impact of electricity price on TCO 177 7.3.2. Impact of node power on TCO 178 7.3.3. Impact of free cooling on TCO 181 7.4. Emerging technologies and their impact on TCO 183 7.4.1. Waste heat reuse 184 7.4.2. Renewable electricity generation 189 7.4.3. Storing excess energy for later reuse 192 7.4.4. Toward a net-zero energy data center 193 Conclusion 195 References 199 Index 209
Trade Policy 买家须知
- 关于产品:
- ● 正版保障:本网站隶属于中国国际图书贸易集团公司,确保所有图书都是100%正版。
- ● 环保纸张:进口图书大多使用的都是环保轻型张,颜色偏黄,重量比较轻。
- ● 毛边版:即书翻页的地方,故意做成了参差不齐的样子,一般为精装版,更具收藏价值。
关于退换货:
- 由于预订产品的特殊性,采购订单正式发订后,买方不得无故取消全部或部分产品的订购。
- 由于进口图书的特殊性,发生以下情况的,请直接拒收货物,由快递返回:
- ● 外包装破损/发错货/少发货/图书外观破损/图书配件不全(例如:光盘等)
并请在工作日通过电话400-008-1110联系我们。
- 签收后,如发生以下情况,请在签收后的5个工作日内联系客服办理退换货:
- ● 缺页/错页/错印/脱线
关于发货时间:
- 一般情况下:
- ●【现货】 下单后48小时内由北京(库房)发出快递。
- ●【预订】【预售】下单后国外发货,到货时间预计5-8周左右,店铺默认中通快递,如需顺丰快递邮费到付。
- ● 需要开具发票的客户,发货时间可能在上述基础上再延后1-2个工作日(紧急发票需求,请联系010-68433105/3213);
- ● 如遇其他特殊原因,对发货时间有影响的,我们会第一时间在网站公告,敬请留意。
关于到货时间:
- 由于进口图书入境入库后,都是委托第三方快递发货,所以我们只能保证在规定时间内发出,但无法为您保证确切的到货时间。
- ● 主要城市一般2-4天
- ● 偏远地区一般4-7天
关于接听咨询电话的时间:
- 010-68433105/3213正常接听咨询电话的时间为:周一至周五上午8:30~下午5:00,周六、日及法定节假日休息,将无法接听来电,敬请谅解。
- 其它时间您也可以通过邮件联系我们:customer@readgo.cn,工作日会优先处理。
关于快递:
- ● 已付款订单:主要由中通、宅急送负责派送,订单进度查询请拨打010-68433105/3213。
本书暂无推荐
本书暂无推荐